  • A contact of AL/AX

    "a contact" is normally opened contact, and It is also called "NO (Normally Opened) contact". More Details >>

    • No:22410
    • Release Date:2018/08/31 14:33
  • B contact of AL/AX

    "b contact" is normally closed contact, and It is also called "NC (Normally Closed) contact". More Details >>

    • No:22435
    • Release Date:2018/08/31 14:33
  • AL/AX/SHT/UVT terminal markings and wire colors

    The color of terminal identification tube and lead wire is same.For one AL switch, 98/ALa terminal : red, 96/ALb terminal : blue, 95/ALc terminal : grayFor S... More Details >>

    • No:22396
    • Release Date:2018/08/31 14:33
  • PAL(Pre-Alarm Module)

    Pre-Alarm is a function which outputs an alarm if the load current exceeds setting current value. This is useful for securing continuous power supply and pre... More Details >>

    • No:22376
    • Release Date:2018/08/31 14:33
  • SHT

    SHT has a burning prevention switch and it does not burn even if external switch remains "ON" state (After the circuit breaker trips, a burning prevention sw... More Details >>

    • No:22355
    • Release Date:2018/08/31 14:33
  • Micro-load AL and AX switch

    It is possible to produce micro-load AL and AX switch for MCCBs/ELCBs. However, if you need the products compatible with the standards (CE marking product an... More Details >>

    • No:22413
    • Release Date:2018/08/31 14:33
  • EAL

    EAL (Earth Leakage Alarm switch) is a switch that electrically displays tripping state of Earth Leakage Circuit Breaker by eartheleakage/ground fault. EAL do... More Details >>

    • No:22404
    • Release Date:2018/08/31 14:33
  • AL

    AL (Alarm switch) is a switch which electrically displays tripping state of a circuit breaker.The markings of the switch are 8/ALa, 96/ALb and 95/ALc.*When t... More Details >>

    • No:22350
    • Release Date:2018/08/31 14:33
  • Insulating barrier in the package

    Use the insulation barrier if they are packed with. If not using that, breaking performance is not guaranteed. For models that the insulation barrier is not ... More Details >>

    • No:22406
    • Release Date:2018/08/31 14:33
  • AL/AX direct connection to PLC

    It is necessary to use AL and AX switches that are suitable for the specification of PLC input unit. Generally AL and AX switch for micro-load are used for i... More Details >>

    • No:22398
    • Release Date:2018/08/31 14:33