Regarding the default IP address
The default IP address (factory default value) of FX5CPU modules is 192.168.3.250. More Details >>
- No:22290
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:33
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Error code "2200" in the universal model QCPU
The error code "2200" is "MISSING PARA.". The cause of the error is that a parameter file does not exist in all drives where parameters will be valid.As a re... More Details >>
- No:22614
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Error 108 (Start not possible) occurs when a start is requested while a stop signal is ON.Check the "[Md.26] Axis operation status".If "20: Servo amplifier ... More Details >>
-
GX Works2's USB driver installation procedure
The USB driver is not installed.The driver needs to be separately installed before the first connection to a CPU module. More Details >>
- No:22507
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding how to check MAC Addresses
You can check the MAC address from the name plate on the side of the CPU module or by the Module diagnostics (CPU diagnostics) of GX Works3. More Details >>
- No:39294
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
"M-code" is outputted to turn ON/OFF machine's solenoids or relays according to the start/end of the positioning operation. The following two modes are sele... More Details >>
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) In the I/O assignment setting of the PLC parame... More Details >>
- No:22650
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:47
- Category: MELSEC-Q Series
-
Changing the display language of device comments with GX Works3
In the multiple comments display setting, you can set a comment title of the device comments to be set. <Displaying the multiple comments display setti... More Details >>
- No:22460
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:46
- Category: MELSEC iQ-R Series
-
When the message "An unusable COM port was specified" is displayed
RS-232 is selected as PC side I/F in Transfer Setup of GX Developer or GX Works2.Change the setting in PC side I/F to USB. More Details >>
- No:22517
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Yes. A USB driver needs to be installed.For the installation procedure, refer to the following manual. - GX Developer Version 8 Operating Manual (Startup) More Details >>
- No:22504
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:10
- Category: MELSEC-Q Series