Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>
- No:24700
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding the type of Ethernet connection cable
Ethernet standard-compatible cable, category 5 or higher (STP cable) can be used. *Straight cable can be used. When connecting directly to the computer, cr... More Details >>
- No:22295
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:23
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the differences between CC-Link IE TSN and CC-Link IE Field Networks
(1)Whether or not networks can be mixed on the same trunk line is different. CC-Link IE TSN allows network mixing on the same trunk line. When using a CC-Li... More Details >>
- No:39359
- Release Date:2023/01/12 17:10
- Category: MELSEC iQ-F Series , Network/Communication
-
Differences between CC-Link IE Control Network and CC-Link IE Field Network
The CC-Link IE Control Network is a high-capacity controller network whose maximum number of link points is 128k words. The CC-Link IE Field Network is an al... More Details >>
- No:23085
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Setting online change in GX Works2
Select [Compile] -> [Online Program Change] from the menu, and execute online change. More Details >>
- No:22940
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:57
- Category: Engineering Software
-
Regarding handling multiple executions of ADPRW Instructions
When multiple ADPRW instructions are simultaneously executed, communication by the ADPRW command that was executed earlier is completed and communication by ... More Details >>
- No:39354
- Release Date:2023/02/15 10:17
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Ethernet-connectable modules in MELSEC-F
The FX3U-ENET-L and FX3U-ENET-ADP are Ethernet-connectable. The FX3U-ENET-L can be used with the FX3U and FX3UC series (both Ver. 2.21 or later). The FX3U-... More Details >>
- No:22270
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
For the sink input, the "S/S" terminal and the "24V" terminal are needed to be short-circuited. More Details >>
- No:22263
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Battery replacement during power-on
Replacethe battery when the programmable controller is powered off. For example, forthe FX3U/FX3UC series, data will be held for about 20 seconds after be... More Details >>
- No:22257
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:54
- Category: MELSEC-F Series , Main Unit , Accessories