Operation error at the execution of a BIN instruction
Keep SM722 ON or correct the program so that any one of the ten numbers 0 to 9 is stored in each digit of the source data.An operation error occurs when data... More Details >>
- No:22635
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
MODBUS(R) interface module's involvement in master and slave stations
Intelligent function module settings allow them to be set in both master and slave stations. More Details >>
- No:22637
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Whether or not totem pole output type encoders are connected
Totem pole output encoders cannot be connected to QD62.The following types of encoders can be connected.- Open collector output type encoders- CMOS level vol... More Details >>
- No:22641
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Yes. More Details >>
- No:22642
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to change the type of statement in GX Developer
Select [Search/Replace] -> [Replace statement/note type] from the menu and select "Change in PLC". More Details >>
- No:22647
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18
- Category: MELSEC-Q Series
-
Parameter settings required to use the MODBUS(R) interface module as a slave station
If preset initial values are used, parameters do not need setting.If changing the basic parameter or MODBUS(R) device assignment parameter, use a sequence pr... More Details >>
- No:22680
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Intelligent function module settings in GX Works2
Modules do not need setting in GX Works2 if not selectable from "Module Selection" in the "New Module" window for intelligent function module settings. More Details >>
- No:22685
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Input derating is the percentage of simultaneous ON points, one of the specifications applied when input modules are used. When QX42 is used in a temperatur... More Details >>
- No:22692
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:23
- Category: MELSEC-Q Series
-
Compatibility between the A series modules and Q series modules
When an ACPU module is replaced with a QCPU module, programs for the ACPU module can be used by changing the PLC type in GX Developer. However, the programs ... More Details >>
- No:22696
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:21
- Category: MELSEC-Q Series