Regarding the effect of battery voltage drop on logging function
Since the battery retains clock data even after power failure, the time of logging data may change. More Details >>
- No:39310
- Release Date:2023/01/12 16:53
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding double-precision real numbers
The FX5 CPU unit does not handle double-precision real numbers. Only single-precision real numbers can be handled. More Details >>
- No:40033
- Release Date:2023/08/24 15:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding printing of cross-references
If cross-references are displayed on GX Works3, you can print them. More Details >>
- No:44619
- Release Date:2024/11/28 16:10
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
How to change the specified connection destination of GX Works3
You can change the destination in [Online]-> [Specify Connection Destination]. Change the destination depending on the communication path to be used. Yo... More Details >>
- No:22472
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:31
- Category: MELSEC iQ-R Series
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Versions of the QJ71C24N modules compatible with QnUDVCPU
The QJ71C24N series modules with serial numbers with upper 5 digits of "10042" or later indicate compatibility with QnUDVCPU. More Details >>
- No:22628
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Q series device data held in the case of a power failure
The data in the devices assigned to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> [Device Setting] window) is held when a pow... More Details >>
- No:22638
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:37
- Category: MELSEC-Q Series
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Programing example of heating/cooling control
The following shows an example of heating/cooling control using split control. * For details, refer to the "Programmable Controllers MELSEC PROC... More Details >>
- No:22719
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:43
- Category: MELSEC-Q Series