Using the VPN (Virtual Private Network)*1 connection service enables the communications. VPN is a technology that connects networks by encrypting the commun... More Details >>
- No:24908
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Network/Communication
-
Positioning blocks/module that can be connected with a manual pulse generator
The FX3U-20SSC-H (differential line driver), FX2N-10PG (differential line driver or open collector: only 5 V type), and FX2N-10GM/FX2N-20GM (open collector) ... More Details >>
- No:24886
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Positioning Control
-
Turn off the drive contact of the WR3A instruction. More Details >>
- No:24872
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Analog Control
-
Connecting the FX3U-ENET-L whose parameters have not been set
When writing parameters first time, write the parameters for Ethernet (data of FX Configurator-RN-L) from a personal computer to a programmable controller ma... More Details >>
- No:24790
- Release Date:2019/02/28 09:08
- Category: MELSEC-F Series , Network/Communication
-
Settings for the FX3U-ENET-ADP
GX Works2 with Ver. 1.87R or later is required. More Details >>
- No:24781
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Comparison result of the CMP instruction
A comparison result is held even after the command input turns off. The remaining comparison result can be cleared by using the RST or ZRST instruction. More Details >>
- No:24692
- Release Date:2019/02/27 08:56
- Category: MELSEC-F Series
-
Order in which a CC-Link master module and slave stations are connected
There is no restriction on the positions of a master station and slave stations where they are connected. (Stations are not required to be connected in order... More Details >>
- No:23041
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link signals checked when an error occurs
Check the following signals.- Module error signal : X0- Host data link status signal: X1- Other station data link status signal: X3 More Details >>
- No:23021
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Mixing the CC-Link IE Field Network with general LAN communication
Mixed communication with the same hub cannot be established. Establish the CC-Link IE Field Network and general LAN communication separately. More Details >>
- No:22988
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:48
- Category: Network related products
-
Terminating resistors for QJ71C24N
A terminating resistor must be connected to the interface in order to reduce signal reflections thus preventing the signal instabilities. More Details >>
- No:22982
- Release Date:2018/09/03 17:31
- Category: Network related products