Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
-
The main units with Ver.3.10 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX ... More Details >>
- No:24990
- Release Date:2019/04/23 10:37
-
Connection of a memory cassette and a display module to the FX3G series main unit
For the 14/24-point type FX3G series main unit, they cannot be connected together. For the 40/60-point type FX3G series main unit, they canbe connected toget... More Details >>
- No:24978
- Release Date:2019/04/23 07:20
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
-
Data collection with FX programmable controller
Data stored in the programmable controller can be saved to a CF card usinga FX3U-CF-ADP CF card special adapter for the FX3U/FX3UC series. More Details >>
- No:24936
- Release Date:2019/04/18 14:24
-
Gratis warranty term of the FX programmable controllers
The longest gratis warranty term after manufacturing shall be eighteen (18) months. For details, refer to the gratis warranty term explained in the applicabl... More Details >>
- No:24928
- Release Date:2019/04/17 11:42
-
Using an expansion board and a special adapter together
In the FX1S/FX1N/FX2N series, only the expansion board for special adapter connection can be used together with the special adapter. In the FX3G series (onl... More Details >>
- No:24906
- Release Date:2019/04/15 11:32
-
The thickness of wireshould be2 square millimeters or more, andclass D grounding (grounding resistance: 100 Ω or less) should be performed. More Details >>
- No:24899
- Release Date:2019/04/15 11:30
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07