Pulse output system of the FX3U-1PG p...
Forward (FP) and reverse (RP) pulse or pulse (PLS) with direction (DIR) can be selected. More Details >>
Differences in the mounting dimension...
The external and mounting dimensions of the FX2N-1PG and the FX3U-1PG are identical. However, the electrical specifications and connectable FX programmable c... More Details >>
Programmable controller series which ...
FX3U/FX3UC series (Ver. 2.20 or later) * To connect the FX3U-1PG to the FX3UC series, the FX2NC-CNV-IF connector conversion adapter or the FX3UC-1PS-5V exte... More Details >>
Operation speed change during a posit...
Yes, it is possible. Write a new value to the operation speed change value (BFM#56, #55) during the positioning operation. * After the operation speed chang... More Details >>
Terminal layout of the FX3U-1PG and F...
Yes, they have the same terminal layout. More Details >>
Output frequency of the FX3U-1PG puls...
It is from 1 Hz to 200 kHz. More Details >>
Whether the positioning parameter is used or the extension positioning parameter is used can be selected in BFM#32 (positioning parameter selection). Select ... More Details >>
Positioning blocks/module that can be...
The FX3U-20SSC-H (differential line driver), FX2N-10PG (differential line driver or open collector: only 5 V type), and FX2N-10GM/FX2N-20GM (open collector) ... More Details >>
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>