FAQ within [ Low-voltage Power Distribution Products ]
-
AL/AX/SHT/UVT terminal markings and wire colors
The color of terminal identification tube and lead wire is same.For one AL switch, 98/ALa terminal : red, 96/ALb terminal : blue, 95/ALc terminal : grayFor S... More Details >>
- No:22396
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
It is overcurrent tripping characteristic zone which exceeds the rated current and does not exceed short time tripping zone (If without short time tripping ,... More Details >>
- No:22384
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
High-speed residual operate CBR
It is Earth Leakage Circuit Breaker that the earth leakage trip operating time at the rated residual operating current (IΔn) is within 0.1 sec, and the earth... More Details >>
- No:22380
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Switch disconnector is a switch compatible with IEC 60947-3 standard, and it has no overcurrent tripping element. Please use it as a switch with large switch... More Details >>
- No:22379
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is a button in order to mechanically trip a circuit breaker outside. It is used to confirm switching mechanism at the regular maintenance or sequence-chec... More Details >>
- No:22368
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is a protection method which only trips the related circuit breaker and other fault-free circuit does not trip and continues power supply in the event of... More Details >>
- No:22366
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
SHT has a burning prevention switch and it does not burn even if external switch remains "ON" state (After the circuit breaker trips, a burning prevention sw... More Details >>
- No:22355
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
The push button is used for testing whether it definitely trips when an earth leakage current occurs. At this test, a Leakage Display button will be come out... More Details >>
- No:22347
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Select rated current sensitivity
Please select rated current sensitivity ,according to the protection purpose and the protective grounding resistance value of the load equipment. If you alre... More Details >>
- No:22346
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
Connectable number of MODBUS RTU (ME96SS series).
It is connectable with up to 31 units. It is necessary to prepare at least 3 PCs for connecting with 64 units. (31 units + 31 units + 2 units) More Details >>