The terminal screw is set in the plastic screw holder and each pole movesone by one. When delivered, the terminal screw is set in the screw holder.When tight... More Details >>
- No:23252
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
The contacts are closed by electrical (closing coil) or mechanical operationand even if the operating force is removed, the closed state is maintainedby the ... More Details >>
- No:23253
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is a current value that can break ( turning contact "OFF") under theconditions specified in the standard. (In IEC, number of tests is 50 times) More Details >>
- No:23261
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It stops a motor rapidly by reversing connetion of a contact. More Details >>
- No:23262
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
At ambient temperature 40℃, the rated voltage (frequency) is applied to acontrol coil, and after temperature rise and saturation, it can operatewithout any t... More Details >>
- No:23278
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is 1500V 50/60Hz between a terminal and a case for 1 min. More Details >>
- No:23310
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
It is the utilization category for opening/closing a heater load ofsemiconductor contactor specified in IEC60947-4-3. Utilization categoryAC-51 applies for "... More Details >>
- No:23318
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
By opening/closing load with SSC of the zero-voltage triggering method, itreduces noise voltage when closing. More Details >>
- No:23323
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
There is a terminal cover for it. ( In MSOD-Q* type magnetic starter, thereis no terminal cover for the thermal load relay although the contactor parthas a t... More Details >>
- No:23330
- Release Date:2018/09/12 15:11
- Category: Motor Starters
-
About Low-voltage Power Distribution Products
Delay-open type magnetic starter (MSO-T*DL and MSO-N*DL type) andmagnetic contactor (S-T*DL and S-N*DL type) have electrolyticcapacitors. Other types do not ... More Details >>