Availability of an option for ME96NS Series (ME96SS series).
An option for ME96NS series can NOT be installed to the main body of ME96SS series. An option for ME96SS series can NOT be installed to the main body of ME... More Details >>
- No:22167
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Operation at the reversed phase connection (ME96SS series).
This model operates normally even at the reversed phase sequence. It is unnecessary to change wiring. More Details >>
- No:22170
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:41
- Category: Electrical Indicators
-
Setting for communication (ME96SS series).
1) For the main body of ME96: Please set the following values on the “Set-up menu 2”. In case of MODBUS RTU Set-up menu No. Setti... More Details >>
- No:22181
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:05
- Category: Electrical Indicators
-
Register address for active energy monitors in the MODBUS RTU communication (ME96SS series).
The acquired digit length of “1280”, “1281” and “1304” varies with the full load power. The acquired digit length of “1304” is 6-digit. Each of “1280” and... More Details >>
- No:22184
- Release Date:2018/08/27 16:41
- Update:2020/04/10 17:18
- Category: Electrical Indicators
-
Concurrent-use of MODBUS RTU and CC-Link.
MODBUS RTU communication and CC-Link communication can be used at the same time. More Details >>
- No:22187
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
Concurrent-use of MODBUS RTU and MODBUS TCP (ME96SS series).
MODBUS RTU communication and MODBUS TCP communication can be used at the same time. More Details >>
- No:22188
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
SHT has a burning prevention switch and it does not burn even if external switch remains "ON" state (After the circuit breaker trips, a burning prevention sw... More Details >>
- No:22355
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
Pre-Alarm is a function which outputs an alarm if the load current exceeds setting current value. This is useful for securing continuous power supply and pre... More Details >>
- No:22376
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
High-speed residual operate CBR
It is Earth Leakage Circuit Breaker that the earth leakage trip operating time at the rated residual operating current (IΔn) is within 0.1 sec, and the earth... More Details >>
- No:22380
- Release Date:2018/08/31 14:33
- Category: Earth Leakage Circuit Breakers
-
It is overcurrent tripping characteristic zone which exceeds the rated current and does not exceed short time tripping zone (If without short time tripping ,... More Details >>
- No:22384
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers