How to install cassette type accessories
A circuit breaker shall be Trip position when installing Cassette type accessory. The breaker may be damaged if installing in "ON" or "OFF" position. Moreove... More Details >>
- No:22422
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
Use with 24V, 0.5A or more for AC and DC in normal use. If the breakers are used less than 24V, use with 6V, 1A or more. Moreover, regular inspection of is ... More Details >>
- No:22401
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
F-type and V-type operating handle
Both of F-type and V-type can remotely operate a circuit breaker in the panel board and the design of 800A fame or less are unified. Features are as follows.... More Details >>
- No:22389
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
No, you must not use 2-pole circuit breaker as 1-pole circuit breaker (series connection as only single phase ). If using it as 1-pole circuit breaker, these... More Details >>
- No:22382
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
It is voltage which ensures withstand voltage and it is used as basis to determine insulation distance. More Details >>
- No:22362
- Release Date:2018/08/31 14:33
- Category: Molded Case Circuit Breakers
-
SHT has a burning prevention switch and it does not burn even if external switch remains "ON" state (After the circuit breaker trips, a burning prevention sw... More Details >>
- No:22355
- Release Date:2018/08/31 14:33
- Category: Accessories and Related Components
-
Support status for IEC61850 (ME96SS series).
This model does NOT comply with the IEC61850. More Details >>
- No:22147
- Release Date:2018/08/27 16:41
- Update:2020/04/10 15:11
- Category: Electrical Indicators
-
Accuracy class index of active energy
Accuracy class index of active energy is a number which gives the limits of the permissible percentage error as defined in the IEC62053-22. More Details >>
- No:37704
- Release Date:2020/01/29 18:36
- Category: Electrical Indicators
-
Wire length for analog output and contact output(ME96SS series)
It depends on the service conditions. Refer to the following guidelines. ① Contact output Contact output for ME96 series is no-voltage "a" contact. The... More Details >>
- No:24807
- Release Date:2019/03/27 12:12
- Category: Electrical Indicators
-
About Low-voltage Power Distribution Products
Reverse connection is possible (connection of load side terminal as powerside and power side terminal as load side). However, it is necessary toinstall a mag... More Details >>
- No:23286
- Release Date:2018/09/12 15:11
- Category: Motor Starters