Regarding FX5 CPU Module clock settings
There are three types of configuration: GX Works3, special devices (SM/SD), and instructions. ・How to Configure in GX Works3 (1) In GX Works3, select On... More Details >>
- No:44365
- Release Date:2024/03/27 17:01
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
M384 to M1535 and D128 to D1099 can be latched. M1536 to M7679, D1100 to D7999, and R0 to R23999 can be used as latch areas by installing an optional batt... More Details >>
- No:24703
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Thecomment may not have been written tothe programmable controller. Or, the comment display setting may be required on the GX Works2 side. [Writing a com... More Details >>
- No:24681
- Release Date:2019/02/22 11:40
- Update:2019/02/22 14:15
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Using a specified bit (on/off) of a word device (D) as a condition for a contact
In the FX3U/FX3UC series, a bit in a word device can be specified. It can be specified by "Word device (D only) + Decimal point + Bit position (0 to F)". A... More Details >>
- No:22261
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Error1201 (HPR data incorrect) occurs when the backup data for absolute position restoration is lost.Execute the machine home position return after checking ... More Details >>
-
Regarding communication with MX Component
For MX Component Ver.5, Ver. 5.000A or later supports the FX5U/FX5UC/FX5UJ CPU modules, and Ver. 5.003D or later supports the FX5S CPU module. Also, both se... More Details >>
- No:22328
- Release Date:2018/08/30 13:55
- Update:2023/02/15 13:07
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
It depends on the servo error.Some can be cleared by "[Cd.5] Axis error reset" but the other cannot unless the servo amplifier's power is turned OFF.Refer to... More Details >>
-
Set "[Cd.16] Inching movement amount", and turn ON the Forward run JOG start signal or the Reverse run JOG start signal. More Details >>
-
The following shows the procedure for changing the current value to a new value.(1) Write the new current value to "[Cd. 9] New current value".(2) Write "900... More Details >>