Identifying disconnected CC-Link stations
Identify disconnected stations using either of the following methods. (1) Select [Diagnostics] -> [CC-Link Diagnostics].from the menu in GX Works2 or G... More Details >>
- No:23053
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:59
- Category: Network related products
-
Difference between AJ65SBTB1-32DT and AJ65SBTB1-32DT2
Major differences are shown below. - AJ65SBTB1-32DT- Leakage current at OFF 0.25 mA or lower- Protection function (overload protection, overvoltage protectio... More Details >>
- No:22985
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
- Category: Engineering Software
-
Using GX Logviewer's realtime monitor function on multiple personal computers
Up to two realtime monitor windows can be used for monitoring.If each of two personal computers monitors one monitor window, two personal computers can be co... More Details >>
- No:22881
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
- Category: Engineering Software
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
The error code "2400" is "FILE SET ERROR". This error may be caused when the file specified with a parameter does not exist. The individual information param... More Details >>
- No:22729
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
- Category: MELSEC-Q Series
-
Memory allocation for online change in GX Works2
The capacity of parameters and programs subtracted from the program capacity for the CPU type in use equals the size of the maximum number of steps. More Details >>
- No:22671
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Use SP.FWRITE instruction to save the data to an ATA card in CSV format.For Q00UJCPU, Q00UCPU, and Q01UCPU, however, memory cards cannot be used thus data ca... More Details >>
- No:22652
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series