FAQ within [ Controllers ]
-
Uncheck "Check battery", an item of "Error Check", in the [PLC RAS setting] ([PLC Parameter] -> [PLC RAS setting]). More Details >>
- No:22681
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:12
- Category: MELSEC-Q Series
-
Ladder programs for GX Configurator-FL
When GX Configurator-FL is used, programs for initial settings and cyclic data reading and writing are not needed. More Details >>
- No:22658
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
CF cards supported by the high speed data logger module
For applicable CF cards, refer to the latest version of the following manual.- High Speed Data Logger Module User's Manual- SH-080818ENG- 2.3 Connection Syst... More Details >>
- No:22607
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The automatic communication function and dedicated instructions (MBRW instruction and MBREQ instruction) can be used on the same channel. However, when the... More Details >>
- No:22577
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:06
- Category: MELSEC-Q Series
-
Is the version of MX Component compatible with Windows 7? Update the software to the version compatible with Windows 7 and then update the driver. For the ... More Details >>
- No:22569
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:50
- Category: MELSEC-Q Series
-
The functional grounding is applied to ensure the reliability of the communication. More Details >>
- No:23076
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference between CC-Link reserved stations and invalid stations
- Reserved station Reserved stations are not actually connected to the network (but will be connected in the future) but do not appear as data link error... More Details >>
- No:22993
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:37
- Category: Network related products
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
- Category: Engineering Software
-
The following Diatrend cable can be used.- DQ-U2 More Details >>
- No:22623
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Receiving data when no receive complete code is designated (QJ71C24N)
Data are received on a received data count basis. If there is no receive complete code and variable length data is received, the data is received at every no... More Details >>
- No:23038
- Release Date:2018/09/03 17:31
- Category: Network related products