Regarding the necessity of using a battery
Device back up is available without using a battery. However, to back up link register (W) and file register (R) devices, a FX3U-32BL (battery) is required. More Details >>
- No:22296
- Release Date:2018/08/30 13:55
- Update:2025/11/07 15:52
- Category: MELSEC iQ-F Series , Option , CPU Module
-
Check the following signals. • Start accept flag (M2001 to M2032) • Positioning start complete signal (M4000+20n (n: Axis No.-1)) More Details >>
-
Regarding the compatible programming tool
GX Developer/GX Works2 cannot be used. MELSEC iQ-F series only supports GX Works3. More Details >>
- No:22292
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:34
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
The power supply lamp of a running programmable controller suddenly turned off or flashes
Check whether the lamp is back to normalafter disconnecting the wiring of the "24V" (service power supply) terminal. Ifthe lamp is back to normal,the servic... More Details >>
- No:22267
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:53
- Category: MELSEC-F Series , Main Unit
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Externally switching the operating status of a programmable controller
On the Project view of the Navigation window, select "Parameter" → "PLC Parameter" using GX Works2 (or GX Developer). Click the "PLC System(1)" tab, and set ... More Details >>
- No:24768
- Release Date:2019/02/27 15:01
- Category: MELSEC-F Series , Engineering Software , Main Unit