FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Installing MX Component Version 3 and 4
No, please install only either of the two. More Details >>
- No:22841
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Battery consumption while the programmable controller is powered on
A battery is consumed regardless of the on/off state ofthe programmable controller. Refer to the User's Manual (Hardware Edition) for the module used, and r... More Details >>
- No:24687
- Release Date:2019/02/22 11:44
- Update:2019/02/22 15:22
- Category: MELSEC-F Series , Main Unit , Accessories
-
To assure 32-bit data, "Network Range Assignment" of the control station must satisfy the following conditions.(1) The start device No. of LB is a multiple o... More Details >>
- No:23052
- Release Date:2018/09/03 17:31
- Category: Network related products
-
MX Component Version 4's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22844
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Detecting the connection between a built-in Ethernet port QCPU and hub
You can check the connection to the hub with bit 10 of the special register SD1288. When bit 10 of the SD1288 is on, the QCPU is in connection with the hub. More Details >>
- No:22712
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
GX Configurator-MB for the MODBUS(R) interface module
GX Configurator-MB does not need to be purchased. Parameters can be set using GX Works2 alone. More Details >>
- No:22701
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Connect with a straight cable using a hub. For more details, refer to the following manual. - FL-net (OPCN-2) Interface Module User's Manual More Details >>
- No:22574
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:55
- Category: MELSEC-Q Series
-
Regarding the processing specification of the basic operation instruction(LD).
The execution time of the basic opeartion instruction (LD) of the FX5U/FX5UC/FX5UJ CPU module is 34 ns. *For firmware Ver.1.100 or above, this specification ... More Details >>
- No:22287
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:56
- Category: MELSEC iQ-F Series , CPU Module
-
Battery replacement during power-on
Replacethe battery when the programmable controller is powered off. For example, forthe FX3U/FX3UC series, data will be held for about 20 seconds after be... More Details >>
- No:22257
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:54
- Category: MELSEC-F Series , Main Unit , Accessories