FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Use the POW (Single Precision Real Power Operation) instruction. More Details >>
- No:40029
- Release Date:2023/08/24 14:38
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding terminal block reuse
Terminal blocks can not be reused. Please rewire it. More Details >>
- No:39365
- Release Date:2023/02/15 13:06
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Connecting special adapters to FX3U series
Anexpansion board is required. (However, it is not required when connecting only the special high-speed I/O adapter.) More Details >>
- No:24934
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Types of data backup methods (FX3G series)
1. Data backup using an optional battery Built-in RAM data and clock data of a programmable controller are held by using an optional battery. The life of... More Details >>
- No:24701
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
PCPU READY complete flag (SM500)
The PCPU READY complete flag (SM500) turns ON when no error is detected in the fixed parameters, servo parameters, and limit switch output data, which are ch... More Details >>
-
PLC type change in GX Developer
Follow the steps below and then execute PLC type change.- On the menu of GX Developer, select [Online] -> [Monitor] -> [Stop Monitoring (All Windows)],... More Details >>
- No:22522
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding the method to check the scan time
The current value of the scan time is stored in the following special devices. Please monitor using GX Works3. ◇Scan information SD520 Current scan time (... More Details >>
- No:22289
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:20
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding Control response parameter of built-in PID Control of CPU Module
The control response parameter can set the response to the target value (SV) of PID control as either "normal" or "fast". The difference is as follows. (1)W... More Details >>
- No:44653
- Release Date:2025/03/18 10:23
- Category: MELSEC iQ-F Series , CPU Module , Analog