Yes. As a guide, the processing time is shown below.For the logging condition, refer to figure 1 below. - For 16 devices: 2 ms - For 64 devices: 6 ms More Details >>
- No:22829
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:33
- Category: MELSEC-L Series
-
Sample comments for special relays/registers
Files are stored as sample comments when GX Developer is installed. Read a comment from the project data of sample comments to a user project and copy a port... More Details >>
- No:22837
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Opening a Structured Text program in GX Developer
Install the latest version again. Check "Structured Text (ST) Language Programming Function" and install it. More Details >>
- No:22862
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with the L series CPU
MX Component Version 4 supports the L series CPU. More Details >>
- No:22867
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Print function of GX Developer
The Print Preview window of GX Developer is a function for checking a print image, made to a specification that allows display of only the first page. A page... More Details >>
- No:22870
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Using GX Logviewer's realtime monitor function on multiple personal computers
Up to two realtime monitor windows can be used for monitoring.If each of two personal computers monitors one monitor window, two personal computers can be co... More Details >>
- No:22881
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
The number of FB definitions created in a project has no limitation. More Details >>
- No:22900
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Index modification in function blocks
Index modification cannot be used for labels. To set index modification, use actual devices as the target devices. More Details >>
- No:22930
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
- Category: Engineering Software
-
Difference between QJ61BT11 and QJ61BT11N
QJ61BT11N supports Version 2 (expanded cyclic setting), the setting for refreshing/forced clearing a slave station data when the switch on a programmable con... More Details >>
- No:22964
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:16
- Category: Network related products