FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
The following seven models are available for the 200 V class: 0.1K, 0.2K, 0.4K, 0.75K, 1.5K, 2.2K, and 3.7K The following five models are available for the 4... More Details >>
- No:21621
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
The same EDS files cannot be used for the different models. Download the EDS files for F800 from the following page of Mitsubishi Electric FA Global Website ... More Details >>
- No:20955
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
Frequency misalignment at current input
It seems that calibration of the current input is slightly incorrect.By using Pr.904 (Frequency setting current bias) and Pr.905 (Gain), you can calibrate th... More Details >>
- No:22014
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The estimated lives of the parts of the FREQROL-E500 are as follows: Cooling fan at surrounding air temperature of 35 deg C???30,000 hrsPower supply smoothin... More Details >>
- No:22071
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Is the forced stop signal wiring necessary?
For the safety of use, the wiring is recommended. If not using the wiring, set the parameter No. PA04 to “0100”. More Details >>
- No:23645
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
The internal transistor of the HC2 stops by turning on the SOF signal and stopping the converter. As a result, regenerative driving is not performed. However... More Details >>
- No:20941
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Control cable between high power factor converter and inverter
Connect the high power factor converter and inverter directly with a control cable, without using a relay. Since a fast-response is required to shut off the ... More Details >>
- No:21555
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
How many inverters can I connect using the communication unit?
Since the communication unit conforms to the EIA Standard RS-485, up to 32 inverters can be connected. (Transmission format: Multidrop link, total wiring len... More Details >>
- No:21616
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Wire length between inverter and motor
1. Wiring length between the inverter and the motor should be 500 m or less. For 0.75 kW or lower motors, the following relationship is true: Capacity... More Details >>
- No:21392
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The value is displayed in 0.1 rpm increments under Vector control. However, the value is rounded down to the first decimal place and displayed in 1 rpm incre... More Details >>
- No:21021
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
1-10 of Total 1368