Because the crimp terminal of 3.5 sq is out of JIS standard. The 5.5 sq crimp terminal can also fix the 3.5 sq cable. More Details >>
- No:20852
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Winding diameter calculation is available for all controls (dancer feedback speed control, tension sensor feedback speed control, tension sensorless torque c... More Details >>
- No:20886
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes, the changed parameters can be displayed with the verification function. Select Parameter list → Verification → Initial value. More Details >>
- No:20918
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, the options are the same as the FR-A800 standard model. Note that two options can be added at maximum. (One option is already used as standard.) Other c... More Details >>
- No:20922
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
No, the update cycle is not changed. More Details >>
- No:21044
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
No, the MT-BU5 is unavailable because it is the conventional model. Use the FR-BU2. More Details >>
- No:21046
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The noise amount does not change because the carrier frequency does not change. More Details >>
- No:21198
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Yes, the resistance values are the same. More Details >>
- No:21020
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
The function is only for overheat protection. It does not affect the torque accuracy. More Details >>
- No:21040
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The parameter file (extension: pr3) can be imported. The system file (extension: mel) cannot be imported. More Details >>
- No:21194
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL