FAQ within [ Drive Products ]
-
The surface temperature of approximately 70?C is OK.The following shows the MM-CF352 frame temperature for reference.(Actual temperature rise depends on how ... More Details >>
- No:21988
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
1. Stall prevention operation works when the inverter's output current exceeds the value set with Pr.22.In this case, it is considered that the current did n... More Details >>
- No:22067
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Yes, it is. More Details >>
- No:20874
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
The operation panel is also compatible with the IP55 More Details >>
- No:21091
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
FR Configurator SW3 (CC-Link Seamless)
It cannot be opened because FR Configurator SW3 and FR Configurator SW3 (CC-Link Seamless) are not compatible. More Details >>
- No:21172
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
The FR-A5AY cannot be used in the FR-A700 (F700(P)). It cannot be installed due to the difference of the connector shape. More Details >>
- No:21260
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
When Advanced magnetic flux vector control (Pr.80, 81) is used, the machine speed constant is controlled. The inverter calculates the motor slip and compensa... More Details >>
- No:21374
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Amount of heat generated by inverter
Refer to Section 2-45 and 2-46 of the FR-A series technical material. More Details >>
- No:21554
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
Calculation of acceleration/deceleration time
As the inverter, you can basically use the equation below to calculate the acceleration/deceleration time.Note that you should consider a factor of 120% for ... More Details >>
- No:21965
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
To supply power via R1 and S1, 60 VA or higher is necessary for 22K or lower and 80 VA or higher is necessary for 30K to 55K.Note that the rush current of ap... More Details >>
- No:22043
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500