FAQ within [ Drive Products ]
-
The processing speed, scan time, and others are slower than those of the programmable controllers. There are some restrictions in the number of I/O points, p... More Details >>
- No:21103
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
Yes. More Details >>
- No:20987
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
The calculation is performed by two modes. One method calculates the current winding diameter automatically by moving the dancer roll from lower limit positi... More Details >>
- No:20924
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>
- No:20889
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Changing multiplication of analog torque command
Yes, it is. For MR-J4-A/MR-J3-A, set by [Pr. PC13]. As the initial value (100.0%), the maximum torque is generated at ±8 V. To generate the maximum torque a... More Details >>
- No:23628
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE , MELSERVO-J3 , MELSERVO Others
-
Installation clearance of inverters
Keep 1 cm or more of clearance for 3.7 K or smaller, and 5 cm or more for 5.5 K or larger.If the clearance is too small, the cooling effect is lowered. Secur... More Details >>
- No:22046
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Relationship between frequency and output torque
The output torque characteristics of the FREQROL-E500 series are shown in the figure below. Figure 1 More Details >>
- No:22024
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The operating environment of FA products
The following surrounding environment is common to all models. Surrounding air temperature: No problem. The inverters can be used in -10 to 50°C. Above sea l... More Details >>
- No:21386
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
No. During JOG operation, deceleration stop is performed even though Pr.250 is set. More Details >>
- No:21199
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
This is because the version of the FR-SW3 is old, and the version of INV is new (Pr.551 = 9999 is added for the products manufactured in December 2011 or lat... More Details >>
- No:21134
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
1021-1030 of Total 1368