FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
I want to drive other manufacturer's motor with PG
You can drive the motor with the FR-V240E-5.5K. However, the following conditions apply: - You need to perform auto tuning because the motor's circuit consta... More Details >>
- No:21539
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
This error depends on the application and the cause is unknown. (The runtime error '31037' is not returned from this application but from the OS (Windows).) ... More Details >>
- No:21495
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Use the first contact (relay) for the forward (or reverse) rotation between the terminals STF and SD. Use the second contact (relay) for the high-speed comma... More Details >>
- No:21472
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Difference between FR-AU01 and AU01A
The major changes from FR-AU01 to FR-AU01A include 1. Case material and 2. Lead wire terminal process method. The FR-AU01A has a backward compatibility with ... More Details >>
- No:21452
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
The FR-E540 uses common input for the control power supply and main circuit power supply. (It has only one power supply input terminal.) Therefore, you canno... More Details >>
- No:21395
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Remote operation of the inverter
The wiring length of the start signal (STF etc.) is 30 m or less. The circuit voltage of the control input signals (terminal STF etc.) is 24 VDC and the volt... More Details >>
- No:21380
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Issues of driving the wound rotor motor inverter
The wound rotor motor can be used in the same way as cage-induction motors by shortening the resistor at the secondary side. More Details >>
- No:21370
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Pr.268 (Monitor decimal digits selection) during CC-Link communication
No, it is not changed. Pr.268 is the parameter for the operation panel. More Details >>
- No:21241
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Monitor code of CC-Link communication
The monitor with the code H01 switches by changing Pr.37 and Pr.144. More Details >>
- No:21236
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is tilted to wire the cable easily. More Details >>
- No:21228
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
1031-1040 of Total 1354