FAQ within [ Drive Products ]
-
The calculation is performed by two modes. One method calculates the current winding diameter automatically by moving the dancer roll from lower limit positi... More Details >>
- No:20924
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes. When Pr.9 = 0, turning is performed with the inverter rated current. Always set the rated motor current. More Details >>
- No:20897
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>
- No:20889
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>
- No:20888
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
No, they do not. Pr.72 is invalid at the offline auto tuning. It is also invalid when the motor rotates with Pr.96 = 101. More Details >>
- No:20878
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
- No:20865
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
Only the FR-A800/F800-E series is supported by CC-Link IE Field Basic. (As of March 2017) The FR-A800-GF and FR-A8NCE supported by CC-Link IE Field are not s... More Details >>
- No:20858
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800 , FREQROL-F800
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
It is less than 1 mA. More Details >>
- No:20836
- Release Date:2018/08/22 16:24
- Category: Options
-
When connecting to the P/+, the current flows in the inrush circuit at the regenerative driving. This regenerative current may generate losses in the inrush ... More Details >>
- No:20815
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
1041-1050 of Total 1353