FAQ within [ Drive Products ]
-
It is protected not by observing the temperature directly, but by estimating it from the current value, output frequency, and carrier frequency. More Details >>
- No:20871
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A700
-
Amount of heat generated by the FR-V500L
It is the same as the one by the inverter whose capacity is one-rank higher than the FR-A500L series. More Details >>
- No:20854
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Setting value of Pr.72 (FR-B, B3 (A800 base))
For the normal type (FR-B3) is 2 KHz. For the low-noise type (FR-B3-N), 14.5 KHz. More Details >>
- No:20828
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-B
-
Safety stop function of the FR-E700/FR-D700
Up to two. More Details >>
- No:20827
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is not supported but can be used. Passive elements such as reactors and brake resistors are out of the scope of the KC (Radio Waves Act (South Korea)). More Details >>
- No:20813
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Switching from star-delta operation
It is probable that the torque is insufficient because the load characteristics and inverter output characteristics do not match and the output current value... More Details >>
- No:22049
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The FM output is 0 to 8 VDC pulse. More Details >>
- No:22039
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Countermeasure against harmonics
The following countermeasure against harmonics is available with the inverter.The values are quoted from the harmonic suppression guidelines.1. Insert the AC... More Details >>
- No:22009
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Reversible operation of agitator
When the inverter's forward and reverse terminals are switched instantaneously, the inverter decelerates and then switches the rotation direction. It can swi... More Details >>
- No:21999
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Current input switching operation
With your setting, since Pr.60 assigns the OH function to the terminal PL, and terminals RL and SD are open, an external protection error occurs. (It does no... More Details >>
- No:21975
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500