FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Wire length between inverter and motor
1. Wiring length between the inverter and the motor should be 500 m or less. For 0.75 kW or lower motors, the following relationship is true: Capacity... More Details >>
- No:21392
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
LED blinking under encoder feedback control
The following may be the cause. - No encoder power supply. - The setting of Pr.359 (Encoder rotation direction) is reversed. - The signal from the encoder is... More Details >>
- No:21219
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Turn ON and OFF the RES signal to enable the inverter-driven operation. More Details >>
- No:21190
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
It is not grounded to the enclosure due to the resin coating. More Details >>
- No:21122
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The setting is enabled at the Y24 start-up. The frequency cannot be changed when Y24 is always ON. Turn ON Y24 when writing a frequency. More Details >>
- No:21048
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>
- No:20888
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Angular velocity change control
The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>
- No:22086
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-V200
-
Switching from star-delta operation
It is probable that the torque is insufficient because the load characteristics and inverter output characteristics do not match and the output current value... More Details >>
- No:22049
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
No. the torque cannot be limited by using Pr.9.Set Pr.277 (Stall prevention current switching) to "1".The value of Pr.22 (Stall prevention operation level) w... More Details >>
- No:21766
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
What parameters (settings) are available?
The following three functions can be set: - Acceleration/deceleration time- Electronic thermal O/L relay- Maximum frequencyThe parameter unit is not used but... More Details >>
- No:21584
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
1051-1060 of Total 1368