FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Using built-in potentiometer and multi-speed together
Yes. Set Pr.79 = 3. (Input the start signal from an external source.) More Details >>
- No:21950
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Can I use a brake resistor with the FR-S500?
The brake unit and its resistor FR-S520-0.4K to 3.7K are available.Mitsubishi Electric FA Global Website also explains so.(Note that the GZG GRZG discharging... More Details >>
- No:21970
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
Notes when inverter capacity is larger than motor capacity
When using one-rank-higher inverter, as you mention, you need to care about the setting of the electronic thermal O/L relay.Setting the electronic thermal O/... More Details >>
- No:22040
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Frequency does not rise with blower
Our suggestion is to adjust the following parameters:1. Set Pr.14 = 0. If the V/F pattern for variable-torque load (Pr.14 = 1) is used, the current may incre... More Details >>
- No:22060
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
We offer DC reactors from 0.4K and you can use it. You can use FR-BIF, FR-BSF, and FR-BEL together. More Details >>
- No:21461
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>
- No:21474
- Release Date:2018/08/22 16:27
- Category: FREQROL-E500
-
The following are check points for abnormal conditions in addition to those given in the FR-Z200 manual. 1. Are the forward and reverse signals input simult... More Details >>
- No:21503
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-Z200
-
Digital input and maximum frequency
1. Pr.1 and 18 limit the output to 120 Hz. Use Pr.18 to change the maximum frequency. 2. If you want to output the binary input as is, setting Pr.304 = 1 (Bi... More Details >>
- No:22098
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500
-
Because when the FR-A8NC and FR-A8TR are used together, the wiring to the terminals becomes physically difficult. More Details >>
- No:20876
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>
- No:21485
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
1071-1080 of Total 1353