FAQ within [ Drive Products ]
-
Installing frequency setting potentiometer
When you are inputting analog signals, install the potentiometer within 30 m from the inverter. (Refer to "Precaution on Selection and Operation" on the cat... More Details >>
- No:22051
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Negative phase of input power supply
The power supplied to the inverter is converted into DC by the converter inside the inverter and then stored in the capacitor. Thus, reversing the phase sequ... More Details >>
- No:22055
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Which motors can I use with the inverter?
You can use general-purpose three-phase induction motors.You can also use geared motors if the motor itself is an induction motor.Synchronous motors are not ... More Details >>
- No:22081
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Yes. More Details >>
- No:20810
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others
-
Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>
- No:20812
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Connection point of the line noise filter
Connect the line noise filter between the inverter and EMC Directive compliant noise filter. More Details >>
- No:20818
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
- No:20821
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Stop-on-contact control of the FR-E700
The stop-on-contact control becomes invalid when the start command is turned OFF during the stop-on-contact control and the machine is decelerated to a stop ... More Details >>
- No:20822
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-E700
-
It is possible when Pr.23 = 0 (Current limit at regenerative driving). More Details >>
- No:20826
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
It is less than 1 mA. More Details >>
- No:20836
- Release Date:2018/08/22 16:24
- Category: Options