FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
No OL signal is output. More Details >>
- No:20870
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>
- No:22072
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Operation command terminal switching
It rotates in the forward direction while STF is ON.And then, when STR is turned ON and STF is turned OFF, the inverter decelerates down to 0 Hz within the s... More Details >>
- No:22070
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Common terminals of control circuit
If you ground the common terminals of the control circuit, it is connected with the inverter's earthing and the inverter's noise may be input to the control ... More Details >>
- No:22037
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Fault contact when connecting separate power supply for each control circuit
Since the inverter's fault contact is an NC contact, it does not open unless a fault occurs.Therefore, when the control power supply (and main circuit power ... More Details >>
- No:22035
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Many geared motors cannot continuously operate at low speed (for example, slower than 6 Hz) due to grease viscosity.If the motor you are using is of this typ... More Details >>
- No:22028
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A024
-
The following benefits are provided when the FR-BLF is installed on the input side or output side.Choose the side to install the FR-BLF considering these ben... More Details >>
- No:22026
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Rated capacity related to harmonic suppression guidelines
The usual inverter input current is determined not by the inverter capacity but by the motor capacity (motor load).Therefore, the input side capacity is not ... More Details >>
- No:21961
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Others
-
Using built-in potentiometer and multi-speed together
Yes. Set Pr.79 = 3. (Input the start signal from an external source.) More Details >>
- No:21950
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
As the motor operates with the electronic thermal O/L relay characteristics for the standard motor, the thermal error occurs if the motor continuously operat... More Details >>
- No:21943
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
1091-1100 of Total 1353