Yes. Use FR-CB20□. More Details >>
- No:21697
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
This error is displayed when the inverter and operation panel FR-PU04 cannot communicate with each other correctly or the reset signal remains ON. Therefore,... More Details >>
- No:21546
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
No load current value of motor
No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>
- No:21534
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
Parameters not covered in manual are displayed
Pr.168 indicates the inverter software version.Pr.169 indicates the inverter software subversion history. These two parameters are only used by the manufactu... More Details >>
- No:21532
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E500
-
Driving German pole change motor by inverter
I cannot tell whether or not you can drive the motor because the electrical specifications are not clear. It is considered that you may drive the pole chang... More Details >>
- No:21518
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Connection with pole change motor
Since the inverter allows for changing speed, fix the number of poles when using the pole change motor. It is recommended to fix the number of poles to four ... More Details >>
- No:21486
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
Since the stall prevention function works during acceleration and the inverter does not reach the commanded speed, set Pr.156 (Stall prevention operation sel... More Details >>
- No:21460
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Can I use a motor of which capacity is larger than the inverter capacity?
Even when the actual load (torque) is half of the motor capacity, the current output from the inverter to the motor is not reduced to the half. Therefore, it... More Details >>
- No:21442
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
When you use a long wire between the inverter and motor, pay attention to the following: 1. Since the voltage supplied to the motor terminal is reduced due t... More Details >>
- No:21441
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Installing reactor for suppressing harmonics
You can connect multiple inverters to a single reactor. In this case, the load seems to be light from the reactor unless all of the inverters are rotating an... More Details >>
- No:21410
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options