FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
No. Check the parameter setting of the A700, and then adjust the parameter setting of the A800 to those of the A700. For the details, refer to the replacemen... More Details >>
- No:21107
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-A700
-
"PS" is displayed when the inverter is stopped with the "STOP/RESET" button from PU. The PU stop (PS) release method is as follows. (1) Release method using ... More Details >>
- No:21264
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Issues of driving the wound rotor motor inverter
The wound rotor motor can be used in the same way as cage-induction motors by shortening the resistor at the secondary side. More Details >>
- No:21370
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
When the inverter output shutoff signal MRS is turned on, the output is shut off immediately without regard to setting of Pr.250. More Details >>
- No:21423
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Difference between FR-AU01 and AU01A
The major changes from FR-AU01 to FR-AU01A include 1. Case material and 2. Lead wire terminal process method. The FR-AU01A has a backward compatibility with ... More Details >>
- No:21452
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Since the FR-A540-0.75K has a brake transistor for resistor regenerative driving inside the inverter, you do not need to use BU. Just remove the jumper from ... More Details >>
- No:21992
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Manual contactor on output side of drive unit
The low-voltage manual contactor is intended to prevent electric shock during inspection and maintenance of the drive unit.The MELIPM series motor is a synch... More Details >>
- No:21996
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Pulse train output of terminal FM
Under Advanced magnetic flux vector control, the output frequency varies due to slip compensation. This may cause the output frequency monitor value to chang... More Details >>
- No:22054
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The one-touch tuning does not require the response level setting also. Outlines of one-touch tuning and auto tuning are as follows: One-touch tuning: You can... More Details >>
- No:23629
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
Which motors can I use with the inverter?
You can use general-purpose three-phase induction motors.You can also use geared motors if the motor itself is an induction motor.Synchronous motors are not ... More Details >>
- No:22081
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
1111-1120 of Total 1353