FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
PBT resin is used for both the FR-A800 and F800. More Details >>
- No:21024
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Sampling time of FR Configurator2
It depends on the mask count. It is approximately 0.125 [ms] (mask count: 1) to 20 [ms] (mask count: 30). More Details >>
- No:20950
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
A1: Blue, A2: White (transparent) More Details >>
- No:20947
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Insulation level of the MM-EFS
F class (155 deg C) More Details >>
- No:20809
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others
-
Motor rated rotations per minute
The inverter is capable of output up to the maximum frequency. It is the matter of whether the motor used support high-speed operation. In the situation you ... More Details >>
- No:22099
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Calculation of inverter acceleration and deceleration time
Refer to the Technical Sheet No.23 (Capacity Selection and Continuous Operation) for reference for selection. Optional capacity selection software is also pr... More Details >>
- No:22097
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Switching between high speed and low speed
As you mention, when the inverter is operated only with STF without inputting the speed command signal, the minimum frequency must be set to 10 Hz.However, a... More Details >>
- No:22078
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
General-purpose magnetic flux vector control is effective at low speed under a heavy load.To shorten the acceleration time, use Pr.44 to set the second accel... More Details >>
- No:22059
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The rotation ripple data for 1.5 kW is shown below.Drive unit: MD-CX520-1.5KMotor: MM-CF152Load: None (motor alone), carrier frequency: 2 kHz, wiring length:... More Details >>
- No:21968
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Fault contact state when input side power supply is cut off
The NC contact does not open when the power supply is cut off whether the inverter is operating or ceased.When the input side power supply is cut off, the DC... More Details >>
- No:21958
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
1111-1120 of Total 1368