Relationship between rotary switch and axis number
When the rotary switch is “0”, the 1st axis and is “1”, the 2nd axis. When the rotary switch is “A”, the 11th axis and is “F”, the 16th axis. In combination ... More Details >>
- No:23644
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
1. You can implement stop-on-contact.2. When implementing stop-on-contact, use the inverter to decelerate the motors to reduce the impact upon stop-on-contac... More Details >>
- No:22041
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The FM output is 0 to 8 VDC pulse. More Details >>
- No:22039
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Using shielded wires for frequency meter connection
Connect the shield to the terminal SD. More Details >>
- No:22034
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
FR-A500 main circuit wire types
Since the UL standard defines to "Use copper wires (rated at 75?C)", we also recommend the same type of copper wire. More Details >>
- No:22032
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Two-rank up maximum short-time torque
It is not possible to generate torque larger than the maximum possible torque of the motor by increasing the inverter's capacity.Even when the inverter is up... More Details >>
- No:22027
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
When the command frequency is 0 Hz, the inverter does not generate output and the voltage is 0 V. More Details >>
- No:22011
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Alarm output signal when using CC-Link
The RX7 output signal is the same as the signals for NO, NC, and transfer contact output.You can change the contents of this output signal using Pr.192.Pr.19... More Details >>
- No:22008
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Before you change Pr.7 and Pr.8, you must switch to the PU operation mode. Switch to the PU operation mode and change them. More Details >>
- No:21984
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
Speed adjustment of multiple inverters using variable resistor
You can connect up to three inverters in parallel to an external variable resistor. Refer to the figure below for a connection example. By setting parameters... More Details >>
- No:21980
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL