FAQ within [ Drive Products ]
-
Pr.38 of the E500 corresponds to Pr.125 (Terminal 2 frequency setting gain frequency) of D700. Pr.39 of the E500 corresponds to Pr.126 (Terminal 4 frequency ... More Details >>
- No:21254
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-D700
-
Dancer control during CC-Link communication
It is not possible under the dancer control. When the negative data is written, it is handled as the positive data in operation. Example) When Pr.541 is set ... More Details >>
- No:21243
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Speed command by CC-Link communication
It is not possible when the speed command is communication. More Details >>
- No:21232
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Checking bit state by CC-Link communication
Because the H0F monitor only observes the ON/OFF of the hardware, it cannot be checked. More Details >>
- No:21230
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Communication EEPROM write selection (Pr.342)
They are cleared by the RES signal from the external terminals or inverter reset from the communication. More Details >>
- No:21221
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
LED blinking under encoder feedback control
The Z-phase signal may be connected to the A-phase or B-phase incorrectly. Check the wiring. More Details >>
- No:21220
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
"E.OSD" occurs when the rotation speed is not decreased for one second despite the start command (STF, STR) is turned OFF. More Details >>
- No:21159
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
At power-ON, the signal turns ON for a moment to perform a converter initial reset. More Details >>
- No:21156
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
It is 0.88 mm2 (AWG18), and 0.3 mm2 (AWG24) for the thermostat. More Details >>
- No:21147
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>
- No:21121
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
1121-1130 of Total 1353