FAQ within [ Drive Products ]
-
For the long wiring (50 m to 100 m) between the servo amplifier and servo motor, there are some precautions (encoder cable, etc.) to note. The wiring is not... More Details >>
- No:23632
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE , MELSERVO-JN , MELSERVO-J3 , MELSERVO Others
-
Using MR Configurator2, you can switch the output signals on/off forcibly independently of the servo status. This function is used for output signal wiring c... More Details >>
- No:23639
- Release Date:2018/09/14 15:10
- Category: Servo Support Software , MELSERVO-J4 , MELSERVO-JE , MELSERVO-JN , MELSERVO-J3
-
Frequency search of the FR-A800/FR-F800
DC voltage is applied when Pr.162 = 0, and AC voltage is applied when Pr.162 = 3 or 13. For the AC, the operation is easier to continue than the DC and the i... More Details >>
- No:20831
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The initial value of Pr.872 is set to "1" (Valid) because the A701 have regeneration unit built-in and an overvoltage may occur when the regenerative operati... More Details >>
- No:20945
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A700
-
No. (Using the copy function causes an error.) Use the FR-DU08 when performing the copy function of the operation panel. More Details >>
- No:21118
- Release Date:2018/08/22 16:26
- Category: FREQROL-A800 , Options , FREQROL-F800
-
Switching between External operation mode and PU operation mode
Assign X16 signal, and set Pr.79 to "0", to switch the operation mode with turning ON/OFF X16 signal. More Details >>
- No:21288
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
It is considered that communication settings between the inverter and personal computer do not match. Check if settings such as communication rate and stop b... More Details >>
- No:21431
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Frequency monitor display fault
This can occur if the parameter unit window display is set to "Frequency setting value". If the screen display selection (first monitored window) is set to "... More Details >>
- No:21526
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
For an inverter with the terminal AU, use the terminal AU. For other inverters, assign the AU function to an unused terminal. And, short-circuit (turn ON) th... More Details >>
- No:21678
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Set Pr.52 (DU/PU main display data selection) to "5".This allows for displaying the setting frequency on the voltage monitor.Then, switch to the monitor mode... More Details >>
- No:21784
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
1161-1170 of Total 1354