FAQ within [ Drive Products ]
-
1. As the measurement condition is unknown, the possible cases are as follows: - If you measured the current on the input side of the inverter, since the cu... More Details >>
- No:21457
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Functions available when using inverter on CC-Link
You can use the regular terminal block wire functions during CC-Link operation. Set Pr.338 (Operation command source) and Pr.339 (Speed command source) to e... More Details >>
- No:21393
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Is the number of writing times of the parameter memory limited?
1. The limit of the parameter writing is 100,000 times. 2. Parameter error occurs. Since the data in the ROM may be broken, the inverter may become unavailab... More Details >>
- No:21385
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Pr.38 of the E500 corresponds to Pr.125 (Terminal 2 frequency setting gain frequency) of D700. Pr.39 of the E500 corresponds to Pr.126 (Terminal 4 frequency ... More Details >>
- No:21254
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-D700
-
Noise effect of CC-Link IE communication
The same test as CC-Link is performed, and we confirmed no problem. More Details >>
- No:21226
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
It decelerates and stops. The operation is the same as the one when the Bit of forward rotation command and reverse rotation command are turned OFF. More Details >>
- No:21222
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no regulation value. Use the inverters in the environment without corrosive gas. More Details >>
- No:21201
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The noise amount does not change because the carrier frequency does not change. More Details >>
- No:21198
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is available on request as a dedicated product. Contact your sales representative. More Details >>
- No:21183
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
They are not insulated. More Details >>
- No:21182
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
1181-1190 of Total 1353