The instantaneous power failure error occurs when the power is turned ON instantaneously (within 100 ms) after the power is turned OFF. When the motor is coa... More Details >>
- No:21388
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The amount of heat generated by the FR-E500 series inverter is registered in the Mitsubishi Electric FA Global Website Member's page. Refer to the technical ... More Details >>
- No:21382
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Remote operation of the inverter
The wiring length of the start signal (STF etc.) is 30 m or less. The circuit voltage of the control input signals (terminal STF etc.) is 24 VDC and the volt... More Details >>
- No:21380
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Wiring of CC-Link communication cable
The communication is established if DA, DB, and DG are connected each other. More Details >>
- No:21239
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote register when instruction code execution request is issued at CC-Link communication
The value "0" is stored. More Details >>
- No:21234
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is fundamentally the same as the conventional model. Considering the recent safety awareness growth, we decided to start supporting it from the FR-HC2. Be... More Details >>
- No:21212
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Data with different capacity can be imported. Data with different voltage or model cannot be imported. More Details >>
- No:21196
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
FR Configurator (English version)
The English version cannot be updated from the Website. FR-SW3-SETUP-WE needs to be purchased. More Details >>
- No:21195
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
1191-1200 of Total 1353