Set the parameters below. For other parameters, keep the initial settings.1. Set Pr.122 (Communication check time interval) to other than "0". ("9999" is OK.... More Details >>
- No:21986
- Release Date:2018/08/22 16:30
- Category: Engineering Software
-
1. It is OK to open MC on the output side while the inverter is operating.2. It is OK to open the input side in case of emergency stop. More Details >>
- No:21972
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Operation of automatic restart after instantaneous power failure
1. No operation log is recorded.2. No. However, you can create a state indicating that automatic restart after instantaneous power failure is in progress by ... More Details >>
- No:21948
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Influence on inverter at motor coasts to stop
An induction motor does not act as a power generator unless voltage is applied to it.Therefore, just rotating due to coasting does not affect the inverter. More Details >>
- No:21940
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
We offer the following: <<Dedicated motor model variation>>- With standard legs (SF-VR__)5.5 kW, 7.5 kW, 11 kW, 15 kW, 18.5 kW, 22 kW, 30 kW, 37 ... More Details >>
- No:21649
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
What type of personal computer is required?
The PC platform can be PC98 or DOS/V as far as Windows 3.1 or Windows 95 runs smoothly, with free space of 1 MB or more on the hard disk, and memory (RAM) 1 ... More Details >>
- No:21591
- Release Date:2018/08/22 16:28
- Category: Engineering Software
-
Connecting operation panel to enclosure
To connect the operation panel to the enclosure, use the parameter unit connection cable FR-CB201, FR-CB203, or FR-CB205. The maximum cable length is 5 m. No... More Details >>
- No:21542
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E500
-
This error depends on the application and the cause is unknown. (The runtime error '31037' is not returned from this application but from the OS (Windows).) ... More Details >>
- No:21495
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Motor characteristics at low input voltage
Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>
- No:21434
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>
- No:21416
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500