FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Installing reactor for suppressing harmonics
You can connect multiple inverters to a single reactor. In this case, the load seems to be light from the reactor unless all of the inverters are rotating an... More Details >>
- No:21410
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Notes on using single-phase 200 V
With the single-phase 200 V input specifications, the input cable current increases. Therefore, choose larger power supply capacity and NF/MC than three-phas... More Details >>
- No:21406
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
The instantaneous power failure error occurs when the power is turned ON instantaneously (within 100 ms) after the power is turned OFF. When the motor is coa... More Details >>
- No:21388
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Operation of the motor with a brake
For the general-purpose inverter, the motor stop cannot be detected accurately because the actual motor speed from a motor is not input. In general, the RUN ... More Details >>
- No:21375
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The output current monitor of the inverter displays the output current effective value of the three phases measured by the current sensor. It does not displa... More Details >>
- No:21373
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Earthing (grounding) of FR-A7NC (E kit)
There is no problem, however, earthing (grounding) from each FG terminal is recommended to avoid the influence of noises. More Details >>
- No:21240
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Wiring of CC-Link communication cable
The communication is established if DA, DB, and DG are connected each other. More Details >>
- No:21239
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
PID control of CC-Link communication
When performing the PID control by CC-Link communication, the X14 signal is disabled. More Details >>
- No:21233
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Speed command by CC-Link communication
It is not possible when the speed command is communication. More Details >>
- No:21232
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
1211-1220 of Total 1368