FAQ within [ Drive Products ]
-
Installing parameter unit outside control panel
You can install the operation panel FR-DU04 (or parameter unit FR-PU04) on the enclosure surface by connecting it with the inverter via a cable.To do this, d... More Details >>
- No:22044
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The FM output is 0 to 8 VDC pulse. More Details >>
- No:22039
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
When the command frequency is 0 Hz, the inverter does not generate output and the voltage is 0 V. More Details >>
- No:22011
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
AC reactor and line noise filter wiring
Basically, either is OK.Both orders are electrically identical, but "1" is recommended since it is preferable to place the line noise filter close to the inv... More Details >>
- No:21964
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
When controlling motor with brake by inverter
Use the RUN signal to turn ON and OFF the brake.Using the MRS (output shutoff) signal to turn ON the brake shuts off the inverter's output and reduces influe... More Details >>
- No:21960
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
When the protective function works, the inverter is stopped (output shutoff) by the RDY signal. More Details >>
- No:21570
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
They are insulated. More Details >>
- No:21242
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Monitor value at CC-Link communication
The data of output frequency, output current, and output voltage are retained at alarm occurrence, but other monitors are not. More Details >>
- No:21235
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
PID control of CC-Link communication
When performing the PID control by CC-Link communication, the X14 signal is disabled. More Details >>
- No:21233
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL