FAQ within [ Drive Products ]
-
It cannot be connected. When using DU08, connect it to the PU connector. More Details >>
- No:21111
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
The inverter overcurrent shut-off fault indication E.OC1, E.OC2, or E.OC3 is not only displayed when the inverter output current reaches approximately 200% o... More Details >>
- No:21519
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>
- No:21976
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500 , FREQROL-F500
-
Negative phase of input power supply
The power supplied to the inverter is converted into DC by the converter inside the inverter and then stored in the capacitor. Thus, reversing the phase sequ... More Details >>
- No:22055
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The FR-PU07(BB) can be used with some restrictions.* The major restrictions are as follows. - Pr.1000 or later cannot be set. - Alarms or warnings that are a... More Details >>
- No:21119
- Release Date:2018/08/22 16:26
- Category: FREQROL-A800 , Options , FREQROL-F800
-
Electronic thermal O/L relay setting
Set Pr.9 to the rated current at 50 Hz or a value 1.1 times as the rated current at 60 Hz.You can specify the motor type with Pr.71 (Applied motor). For a co... More Details >>
- No:21941
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The brake resistor is not built in the inverter. Purchase the optional resistor and connect it to the inverter.Inverter only (without resistor)Continuous reg... More Details >>
- No:21989
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Monitoring function of the FR-A800-R2R
Line speed command and Line speed pulse monitor can be monitored while the operation is stopping. Actual line speed monitor becomes "0" while the operation i... More Details >>
- No:20914
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>
- No:20981
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Plug-in Options