FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
For 200 V: The cover is attached for 15 K or lower. No cover is attached for 18.5 K or higher. For 400 V: The cover is attached for 55 K or lower. No cover i... More Details >>
- No:20988
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:20987
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:20986
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:20985
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
□□□□□□ Year Month (Control number) The last digit of the manufactured year is indicated as the Year, and the Month is indicated by (A → B → C... ⇒ January → ... More Details >>
- No:20983
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
□□□□□□ Year Month (Control number) The last digit of the production year is indicated as the Year, and the Month is indicated by 1 to 9, X (October), Y (Nove... More Details >>
- No:20982
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>
- No:20981
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
It is based on the maximum value that can be set for frequency. Specifically, it is 400 Hz. More Details >>
- No:20979
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
UVT will occur when reactor is not connected. Always connect a reactor that matches the motor capacity. More Details >>
- No:20978
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
No alarm occurs due to the abnormal temperature. In the main circuit, alarms such as heatsink overheat will be occurred. More Details >>
- No:20977
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
1251-1260 of Total 1368