FAQ within [ Drive Products ]
-
Inverter installation when using the FR-A7NCE
Normally, the required space for A700 3.7K or lower is 1 cm. However, when using CC-Link IE, it needs to be separated for 5 cm or more to pass the cable. More Details >>
- No:21227
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Reading during the operation is possible. However, when writing is performed during the operation, "rE2" (parameter write error) occurs. More Details >>
- No:21215
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Refer to the inverter capacity. More Details >>
- No:21200
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
They are not insulated. More Details >>
- No:21182
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
Setting when using the FR-A7AZ and SF-V5RU
Setting of Pr.408 (Thermistor selection) is required. Set as follows. For the model of SF-V5RU ending with "T" (SF-V5RU○○T): Pr.408 = 0 For the model of SF-V... More Details >>
- No:21169
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
FR-FS-0.4K: 35 W, FR-FS-0.8K: 65 W, Noise filter: 4 W More Details >>
- No:21165
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Parts arrangement is available. Consult with your sales agent. More Details >>
- No:21129
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
JIS standard for the inverter is not established. It is required to check whether the whole machine including the inverter is compliant with JIS standard. More Details >>
- No:21023
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is. More Details >>
- No:20968
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Waiting time at the instantaneous power failure
The count is started from the power failure. The count is started after the power restoration or reset release when the power failure period is too long, or ... More Details >>
- No:20939
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL