FAQ
FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Change Pr.161 (Frequency setting/key lock operation selection) to "1" (potentiometer mode). More Details >>
- No:21792
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
How can I have the motor coast to stop?
You can use the following two methods:1. Turn ON MRS at the same time when STF turns OFF.2. Set Pr.10 = 60 Hz, Pr.11 = 0 sec, and Pr.12 = 0% (when the invert... More Details >>
- No:21967
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The inverter does not have a function to limit the current at 0 Hz.Although it has the DC injection brake, it is intended to improve the braking capability b... More Details >>
- No:22002
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Impossible to recover after power failure
First, ensure that the parameter for automatic restart after instantaneous power failure is set correctly and then do the following:1. Check if the terminals... More Details >>
- No:22033
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
1. The braking torque can be considered 50% of the motor rated torque.2. The largest stress the DC injection brake gives to the motor is the motor heat gener... More Details >>
- No:22088
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Inverter installation interchange attachment
Use the FR-A5AT02 as the intercompatibility attachment when upgrading from the FR-A220-3.7K to FR-A540-3.7K. More Details >>
- No:22095
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Relationship between rotary switch and axis number
When the rotary switch is “0”, the 1st axis and is “1”, the 2nd axis. When the rotary switch is “A”, the 11th axis and is “F”, the 16th axis. In combination ... More Details >>
- No:23644
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Depending on each cable. Refer to each SSCNET III/H compatible servo amplifier instruction manual. More Details >>
- No:23652
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
The English version of SW3 can be installed with the product ID of FR Configurator2 if it is Ver.5.50 or later. Since Ver.5.50 or former does not have a prod... More Details >>
- No:20913
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
1261-1270 of Total 1368