FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Winding diameter calculation of the FR-A800-R2R
Z phase is not required for the thickness method. More Details >>
- No:20855
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
Amount of heat generated by the FR-V500L
It is the same as the one by the inverter whose capacity is one-rank higher than the FR-A500L series. More Details >>
- No:20854
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Current increase at motor stop
If the current increases when the motor stops under V/F control (at low speed under a light load), the motor is considered to be in the overexcitation state.... More Details >>
- No:21997
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
This error depends on the application and the cause is unknown. (The runtime error '31037' is not returned from this application but from the OS (Windows).) ... More Details >>
- No:21495
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Shielded wiring of external speed setting potentiometer
Grounding can often get dirty due to influence from the inverter main circuit switching. Therefore, when the potentiometer shielded wire is connected to the ... More Details >>
- No:21455
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
After inputting the start signal performing the tuning, output the output frequency. The tuning ends in approximately 500 ms in maximum after started. Durin... More Details >>
- No:21372
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Because the multi-speed terminal is disabled, it does not operate in multi-speed. More Details >>
- No:21205
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The function block and ladder language are available. The ST language is not available. More Details >>
- No:21043
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Using a motor dedicated to the direct connection (with a creep-free bearing) may result in a bearing noise. More Details >>
- No:20963
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
-
Safety stop function of the FR-E700/FR-D700
Up to two. More Details >>
- No:20827
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
1261-1270 of Total 1353