FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
It is set to "1" (cooling fan ON-OFF control enabled). More Details >>
- No:21131
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-F700PJ
-
Number of terminals: There are the same output terminals as A700 and the following terminals (2 points) are added. Safety: SO, SOC * The terminals SO and SOC... More Details >>
- No:21098
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
The specifications are the same. The same cable gauge is available. More Details >>
- No:21052
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The CC-Link communication can be supported by using option FR-A7NC E kit. More Details >>
- No:21031
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, the current is limited under the PM sensorless control. More Details >>
- No:20936
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
The tension controller is suitable for the equipment with low speed and small capacity. The tension controller is suitable for the equipment with low speed a... More Details >>
- No:20929
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Vector control cannot be selected unless Pr.862 is set to 1. (Only the first motor is supported in the motor setting of FR Configurator2.) More Details >>
- No:20908
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
It is not supported but can be used. Passive elements such as reactors and brake resistors are out of the scope of the KC (Radio Waves Act (South Korea)). More Details >>
- No:20813
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Influence on external measurement device
It is considered that malfunction of the measurement device is due to noise. Check the noise propagation route since the countermeasure depends on it. Some c... More Details >>
- No:22100
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Others
1281-1290 of Total 1368