It is 1 mA as the 700 series. More Details >>
- No:21204
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Reading during the operation is possible. However, when writing is performed during the operation, "rE2" (parameter write error) occurs. More Details >>
- No:21215
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
LED blinking under encoder feedback control
The Z-phase signal may be connected to the A-phase or B-phase incorrectly. Check the wiring. More Details >>
- No:21220
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Noise effect of CC-Link IE communication
The same test as CC-Link is performed, and we confirmed no problem. More Details >>
- No:21226
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Inverter installation when using the FR-A7NCE
Normally, the required space for A700 3.7K or lower is 1 cm. However, when using CC-Link IE, it needs to be separated for 5 cm or more to pass the cable. More Details >>
- No:21227
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
The signal becomes 0 when the RES signal is turned ON. More Details >>
- No:21238
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Pr.38 of the E500 corresponds to Pr.125 (Terminal 2 frequency setting gain frequency) of D700. Pr.39 of the E500 corresponds to Pr.126 (Terminal 4 frequency ... More Details >>
- No:21254
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-D700
-
Issues of driving the wound rotor motor inverter
The wound rotor motor can be used in the same way as cage-induction motors by shortening the resistor at the secondary side. More Details >>
- No:21370
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Using FR-A540 inverter on CC-Link
Answer to question 1 When the CC-Link option goes faulty, OPT (option error) occurs and the inverter's fault output is triggered. When communication is lost ... More Details >>
- No:21391
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Countermeasure against harmonics
When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>
- No:21398
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others