FAQ within [ Drive Products ]
-
Because RSO (converter reset) of the HC2 is connected to RES of the inverter, the inverter is reset along with the HC2 reset. (Refer to the wiring diagram in... More Details >>
- No:20948
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
It is the length from the support of the rope to the center of gravity of the swinging. More Details >>
- No:20934
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is preferred. The accuracy becomes worse when the gap between the setting value and actual value increases. More Details >>
- No:20932
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The anti-sway control can be performed with the inverter alone. More Details >>
- No:20930
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is. However, it is not suitable for the low speed regenerative side. It is also recommended to use a dedicated control for winding/unwinding applicat... More Details >>
- No:20928
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes. When Pr.9 = 0, turning is performed with the inverter rated current. Always set the rated motor current. More Details >>
- No:20897
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes, they are. More Details >>
- No:20877
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Amount of heat generated by the FR-V500L
It is the same as the one by the inverter whose capacity is one-rank higher than the FR-A500L series. More Details >>
- No:20854
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Frequency setting by the CC-Link
When the frequency setting value is written by the CC-Link to EEPROM, the frequency setting value set with the PU (operation panel) is changed. More Details >>
- No:20851
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Leakage current of the FR-HAL/FR-HEL
It is less than 1 mA. More Details >>
- No:20844
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options