FAQ within [ Drive Products ]
-
The power factor is 0.99 or more (at rated load). More Details >>
- No:20803
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Can I replace the cooling fan alone?
The fan of the FR-A024 cannot be replaced by the customer. Mitsubishi Electric System & Service will replace it, so contact us to order it. More Details >>
- No:22001
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A024
-
No load current value of motor
No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>
- No:21534
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
Yes. More Details >>
- No:20959
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A700
-
No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>
- No:20952
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
When the protective function works, the inverter is stopped (output shutoff) by the RDY signal. More Details >>
- No:21570
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Positioning is available by inputting pulse trains to the terminal JOG, same as the A700 series. More Details >>
- No:21104
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
It is less than 1 mA. More Details >>
- No:20836
- Release Date:2018/08/22 16:24
- Category: Options
-
The resistor unit MT-BR5 manufactured in February 2016 or later has output terminal TH3 (NC contact) as a fault output terminal. More Details >>
- No:20816
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
1301-1310 of Total 1368