FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Since the heat sink and fan are not waterproof, you need to enclose them so that they are not exposed to the spray of water. If you use the inverter (heat si... More Details >>
- No:21433
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The operating environment of FA products
The following surrounding environment is common to all models. Surrounding air temperature: No problem. The inverters can be used in -10 to 50°C. Above sea l... More Details >>
- No:21386
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Issues of driving the wound rotor motor inverter
The wound rotor motor can be used in the same way as cage-induction motors by shortening the resistor at the secondary side. More Details >>
- No:21370
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
It is available since June, 2007. The model is FR-E7TR. More Details >>
- No:21300
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
Dancer control during CC-Link communication
It is not possible under the dancer control. When the negative data is written, it is handled as the positive data in operation. Example) When Pr.541 is set ... More Details >>
- No:21243
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Monitor value at CC-Link communication
The data of output frequency, output current, and output voltage are retained at alarm occurrence, but other monitors are not. More Details >>
- No:21235
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Speed command by CC-Link communication
It is not possible when the speed command is communication. More Details >>
- No:21232
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
No, they are not connected inside the inverter. More Details >>
- No:21225
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
1311-1320 of Total 1368