FAQ
FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Yes, the changed parameters can be displayed with the verification function. Select Parameter list → Verification → Initial value. More Details >>
- No:20918
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The frequency setting in the communication cannot be used together with FR-A8AX. The priority of the FR-A8AX is equal to the second terminal analog input and... More Details >>
- No:20917
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
Monitoring function of the FR-A800-R2R
No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>
- No:20915
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Vector control cannot be selected unless Pr.862 is set to 1. (Only the first motor is supported in the motor setting of FR Configurator2.) More Details >>
- No:20908
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>
- No:20904
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Terminal 2 input selector switch when the PTC thermistor is connected
When the DIP switch is changed to I, it does not operate normally because the internal resistance changes. More Details >>
- No:20901
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes, they are. More Details >>
- No:20900
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes. When Pr.9 = 0, turning is performed with the inverter rated current. Always set the rated motor current. More Details >>
- No:20897
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is available if the CC-Link option of the FR-A8NC is installed. More Details >>
- No:20894
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes. Use the coated model, FR-A8NC-60. More Details >>
- No:20892
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
1321-1330 of Total 1368