FAQ within [ Drive Products ]
-
The new function includes:- PI control function- Cumulative energy monitor (monitor accuracy: approximately ±25% of full scale value)- Response current limit... More Details >>
- No:21660
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A100
-
Yes. (However, you need to use the parameter unit connection cable FR-CBL (option).) More Details >>
- No:21604
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Harmonic Suppression Guidelines
The harmonics generation device manufacturer application form must be created by the manufacturer and submitted by the consumer when a device that contains a... More Details >>
- No:21507
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Although you can connect an analog or digital indicator to the terminal FM, use an analog indicator since the wiring length is long. (The maximum wiring leng... More Details >>
- No:21415
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Monitor value at CC-Link communication
The data of output frequency, output current, and output voltage are retained at alarm occurrence, but other monitors are not. More Details >>
- No:21235
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
They are not received during the operation. They are also not received if the command authority does not exist in the communication. When they are executed i... More Details >>
- No:21223
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is fixed to 5 kHz. More Details >>
- No:21211
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
FR Configurator (English version)
The English version cannot be updated from the Website. FR-SW3-SETUP-WE needs to be purchased. More Details >>
- No:21195
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Yes. More Details >>
- No:21034
- Release Date:2018/08/22 16:25