Pulse frequency characteristics of terminal FM
The terminal FM output pulse is directly proportional to the inverter output frequency.With the initial setting, 1440 pulses/sec are output at 60 Hz (Pr.55),... More Details >>
- No:22080
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Since the brake sequence function requires Advanced magnetic flux vector control and advanced flux control is applied to 0.4 kW or higher motors, you cannot ... More Details >>
- No:22075
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Imbalanced input side power supply
1. Power supply voltage phase imbalance toleranceMitsubishi inverter's input power supply voltage phase imbalance tolerance is ±3%.If the phase imbalance exc... More Details >>
- No:21987
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Pr.268 (Monitor decimal digits selection) during CC-Link communication
No, it is not changed. Pr.268 is the parameter for the operation panel. More Details >>
- No:21241
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>
- No:21161
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
Yes, the options are the same as the FR-A800 standard model. Note that two options can be added at maximum. (One option is already used as standard.) Other c... More Details >>
- No:20922
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Terminal 2 input selector switch when the PTC thermistor is connected
When the DIP switch is changed to I, it does not operate normally because the internal resistance changes. More Details >>
- No:20901
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>
- No:20812
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Thickness of coating and length of cable provided More Details >>
- No:23651
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE
-
As the motor operates with the electronic thermal O/L relay characteristics for the standard motor, the thermal error occurs if the motor continuously operat... More Details >>
- No:21943
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL