FAQ within [ Drive Products ]
-
Priorities are: Low speed (RL) > Middle speed (RM) > High speed (RH).For example, if the low speed (RL) and middle speed (RM) signals are input simulta... More Details >>
- No:21772
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Multi-speed setting and external potentiometer
The multi-speed setting is prioritized.The external potentiometer setting is effective when the multi-speed signal is not input. More Details >>
- No:21773
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Up to 30 m. (To avoid noise and voltage drop) More Details >>
- No:21910
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
1. Stall prevention operation works when the inverter's output current exceeds the value set with Pr.22.In this case, it is considered that the current did n... More Details >>
- No:22067
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
If Pr 27 is not set, the operation starts at the speed of RL. More Details >>
- No:21123
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Connecting ammeter to output side
Yes. Use a moving-iron type ammeter. However, if the carrier frequency exceeds 5 kHz, do not use that meter since an overcurrent losses produced in the inter... More Details >>
- No:21681
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
If Pr.79 = 3, PU and EXT turn ON. Switching between PU and EXT is not available. Turn the setting dial to set the frequency and press the SET key to accept it. More Details >>
- No:21695
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Switching between External operation mode and PU operation mode
Assign X16 signal, and set Pr.79 to "0", to switch the operation mode with turning ON/OFF X16 signal. More Details >>
- No:21288
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
The coasting time is the time from when the brake power is turned off until the brake starts braking. The coil has the characteristic that electric current t... More Details >>
- No:20775
- Release Date:2018/08/21 16:10
- Update:2018/09/07 12:40
- Category: Geared Motors Parallel shaft type , Geared Motors Right angle shaft type , S-PM Geared Motors Parallel shaft type , S-PM Geared Motors Right angle shaft type
-
High-efficiency standards in foreign countries
As of April 2018, there are no high-efficiency standards.However, there is a movement to start regulation with capacity of 0.12kW or more from 2020, so you h... More Details >>
- No:20785
- Release Date:2018/08/21 16:10
- Category: Geared Motors Parallel shaft type , Geared Motors Right angle shaft type , S-PM Geared Motors Parallel shaft type , S-PM Geared Motors Right angle shaft type