It is possible by using the terminal A to C with the negative logic setting. More Details >>
- No:21203
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is 0.88 mm2 (AWG18), and 0.3 mm2 (AWG24) for the thermostat. More Details >>
- No:21147
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The FR-ASF may be damaged due to the surge voltage. More Details >>
- No:20989
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
It is 12 bits (4096). More Details >>
- No:20969
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Waiting time at the instantaneous power failure
The count is started from the power failure. The count is started after the power restoration or reset release when the power failure period is too long, or ... More Details >>
- No:20939
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It depends on machine specifications. It depends on the accuracy of the line speed input and parameter setting of material thickness. More Details >>
- No:20927
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It is 2 to 3 ms, same as the FR-A800. More Details >>
- No:20819
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Fault contact when connecting separate power supply for each control circuit
Since the inverter's fault contact is an NC contact, it does not open unless a fault occurs.Therefore, when the control power supply (and main circuit power ... More Details >>
- No:22035
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Yes. More Details >>
- No:21749
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Connecting voltmeter to terminal AM
You can connect them in parallel. Connect the voltmeters in parallel, paying attention to the following: - The output current should not exceed the permissib... More Details >>
- No:21464