Installing magnetic contactor on input side of inverter
Basically, there is no difference between the A200 and A500. For safer use, from the A500, it is recommended to completely shut off the power supply by turni... More Details >>
- No:21466
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Operation of the motor with a brake
For the general-purpose inverter, the motor stop cannot be detected accurately because the actual motor speed from a motor is not input. In general, the RUN ... More Details >>
- No:21375
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Inverter operation at instantaneous power failure
When performing the automatic restart after instantaneous power failure, input the operation signal (STF or STR) and selection of automatic restart after ins... More Details >>
- No:21371
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no setting to disable it, but setting a high torque limit level such as 400 % can disable the limit. More Details >>
- No:21217
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Overshooting of the speed due to the acceleration/deceleration may be the cause. Overshooting is more likely to occur when the load inertia is too high. As a... More Details >>
- No:21216
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is not output in the JOG operation mode. More Details >>
- No:21214
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Yes. However, it is difficult to wind the twisted wires because they are thick. More Details >>
- No:21128
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:21041
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The function is only for overheat protection. It does not affect the torque accuracy. More Details >>
- No:21040
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL